Baluster Spacing Calculator
HoneyDoMath.com
Enter the clear length between two posts, the width of your balusters and the largest gap you choose, and get the count, the gap between balusters, the spacing from centre to centre and every mark to measure from.
Estimates for planning, not professional advice. Read the full notice.
Example: Baluster spacing strip
Enter the numbers above to see your drawing.
Summary
- Balusters
- 19
- Gap
- 87 mm
- Spacing, centre to centre
- 127 mm
- First baluster, left edge
- 87 mm
- First baluster, centre
- 107 mm
Estimate for planning, from what you entered and the product data shown. Check product labels and your supplier before you buy.
Baluster spacing strip
Marks from the start
| Baluster | Left edge | Centre |
|---|---|---|
| Baluster 1 | 87 mm | 107 mm |
| Baluster 2 | 214 mm | 234 mm |
| Baluster 3 | 341 mm | 361 mm |
| Baluster 4 | 468 mm | 488 mm |
| Baluster 5 | 595 mm | 615 mm |
| Baluster 6 | 722 mm | 742 mm |
| Baluster 7 | 849 mm | 869 mm |
| Baluster 8 | 976 mm | 996 mm |
| Baluster 9 | 1,103 mm | 1,123 mm |
| Baluster 10 | 1,230 mm | 1,250 mm |
| Baluster 11 | 1,357 mm | 1,377 mm |
| Baluster 12 | 1,484 mm | 1,504 mm |
| Baluster 13 | 1,611 mm | 1,631 mm |
| Baluster 14 | 1,738 mm | 1,758 mm |
| Baluster 15 | 1,865 mm | 1,885 mm |
| Baluster 16 | 1,992 mm | 2,012 mm |
| Baluster 17 | 2,119 mm | 2,139 mm |
| Baluster 18 | 2,246 mm | 2,266 mm |
| Baluster 19 | 2,373 mm | 2,393 mm |
Drawing
A strip of 19 balusters. The mark table lists every mark.
Scale 1:20 when printed at 100% (actual size).
Example: a rail with balusters
19 balusters
- Balusters 19 balusters
- Handrail 3 handrail lengths, metres
Result
Enter a size to see your total.
Each product is rounded up once for the whole project, so the total can be less than the items bought alone added together. A line counted from a cut layout (sheets, boards or tiles laid out piece by piece) is counted for each item and added.
- Balusters 19
- Handrail, Handrail length, metres 3
Questions
How many balusters do I need for a guard?
Enter the clear length between the posts, the baluster width and the largest gap you choose. The calculator finds the fewest balusters that keep every gap at or under that gap, then shares the space evenly between them.
Why does the page not state a rule for the gap?
The largest gap is your own entry, with an example filled in. The rule that applies depends on where you build, so check it with your municipal building department; this page only lays out the balusters for the gap you choose.
Can the balusters sit flush to the posts?
Yes. Choose flush to both ends, or flush at the start only, and the calculator recounts the balusters and the gaps for that layout.
Worked example: a rail with balusters
Show the steps
- Balusters: the fewest that leave every gap at or under the largest gap, rounded up once 2.5 m (8 ft 2 7/16 in) ÷ 90 mm (3 9/16 in) = 19 balusters
- Gap: the clear length less the width of every baluster, shared between the gaps (one more gap than balusters) 2.5 m (8 ft 2 7/16 in) = 87 mm (3 7/16 in)
- Spacing from centre to centre: the gap plus one baluster width 87 mm (3 7/16 in) + 40 mm (1 9/16 in) = 127 mm (5 in)
- First baluster, left edge: one gap from the post 87 mm (3 7/16 in) = 87 mm (3 7/16 in)
- First baluster, centre: the left edge plus half a baluster width 87 mm (3 7/16 in) = 107 mm (4 3/16 in)
Baluster marks for this example
Where each baluster sits, measured from the start of the clear length: left edge, centre and right edge
| Baluster | Left edge | Centre | Right edge |
|---|---|---|---|
| Baluster 1 | 87 mm (3 7/16 in) | 107 mm (4 3/16 in) | 127 mm (5 in) |
| Baluster 2 | 214 mm (8 7/16 in) | 234 mm (9 3/16 in) | 254 mm (10 in) |
| Baluster 3 | 341 mm (1 ft 1 7/16 in) | 361 mm (1 ft 2 3/16 in) | 381 mm (1 ft 3 in) |
| Baluster 4 | 468 mm (1 ft 6 7/16 in) | 488 mm (1 ft 7 3/16 in) | 508 mm (1 ft 8 in) |
| Baluster 5 | 595 mm (1 ft 11 7/16 in) | 615 mm (2 ft 3/16 in) | 635 mm (2 ft 1 in) |
| Baluster 6 | 722 mm (2 ft 4 7/16 in) | 742 mm (2 ft 5 3/16 in) | 762 mm (2 ft 6 in) |
| Baluster 7 | 849 mm (2 ft 9 7/16 in) | 869 mm (2 ft 10 3/16 in) | 889 mm (2 ft 11 in) |
| Baluster 8 | 976 mm (3 ft 2 7/16 in) | 996 mm (3 ft 3 3/16 in) | 1.016 m (3 ft 4 in) |
| Baluster 9 | 1.103 m (3 ft 7 7/16 in) | 1.123 m (3 ft 8 3/16 in) | 1.143 m (3 ft 9 in) |
| Baluster 10 | 1.23 m (4 ft 7/16 in) | 1.25 m (4 ft 1 3/16 in) | 1.27 m (4 ft 2 in) |
| Baluster 11 | 1.357 m (4 ft 5 7/16 in) | 1.377 m (4 ft 6 3/16 in) | 1.397 m (4 ft 7 in) |
| Baluster 12 | 1.484 m (4 ft 10 7/16 in) | 1.504 m (4 ft 11 3/16 in) | 1.524 m (5 ft) |
| Baluster 13 | 1.611 m (5 ft 3 7/16 in) | 1.631 m (5 ft 4 3/16 in) | 1.651 m (5 ft 5 in) |
| Baluster 14 | 1.738 m (5 ft 8 7/16 in) | 1.758 m (5 ft 9 3/16 in) | 1.778 m (5 ft 10 in) |
| Baluster 15 | 1.865 m (6 ft 1 7/16 in) | 1.885 m (6 ft 2 3/16 in) | 1.905 m (6 ft 3 in) |
| Baluster 16 | 1.992 m (6 ft 6 7/16 in) | 2.012 m (6 ft 7 3/16 in) | 2.032 m (6 ft 8 in) |
| Baluster 17 | 2.119 m (6 ft 11 7/16 in) | 2.139 m (7 ft 3/16 in) | 2.159 m (7 ft 1 in) |
| Baluster 18 | 2.246 m (7 ft 4 7/16 in) | 2.266 m (7 ft 5 3/16 in) | 2.286 m (7 ft 6 in) |
| Baluster 19 | 2.373 m (7 ft 9 7/16 in) | 2.393 m (7 ft 10 3/16 in) | 2.413 m (7 ft 11 in) |
Each mark is worked out from its own place in the run, then written to the nearest millimetre. Marks are never added up from the rounded spacing, which would drift.
Balusters per section
Balusters, gap and spacing from centre to centre for common clear lengths, at the example baluster width and largest gap
| Clear length | Balusters | Gap | Centre to centre |
|---|---|---|---|
| 1 m (3 ft 3 3/8 in) | 7 balusters | 90 mm (3 9/16 in) | 130 mm (5 1/8 in) |
| 1.5 m (4 ft 11 1/16 in) | 11 balusters | 88.3 mm (3 1/2 in) | 128.3 mm (5 1/16 in) |
| 2 m (6 ft 6 3/4 in) | 15 balusters | 87.5 mm (3 7/16 in) | 127.5 mm (5 in) |
| 3 m (9 ft 10 1/8 in) | 23 balusters | 86.7 mm (3 7/16 in) | 126.7 mm (5 in) |
Every row leaves a gap at each end and uses the example baluster width and largest gap of this page.
What the National Building Code of Canada 2020 prints for guards
Openings through guards and guard height, Articles 9.8.8.5 and 9.8.8.3 of the National Building Code of Canada 2020, Part 9 (a model code; provinces and territories adopt it, some with changes)
| Figure | Value in the code |
|---|---|
| Sphere that must not pass through an opening, diameter | 100 mm (3 15/16 in, converted) |
| Sphere that must not pass through the triangular openings beside stairs, diameter | 150 mm (5 7/8 in, converted) |
| Guard height, at least | 1,070 mm (3 ft 6 1/8 in, converted) |
| Guard height within a dwelling unit, at least | 900 mm (2 ft 11 7/16 in, converted) |
Source: [1]
Model-code figures, with conditions the code lists. Provinces and territories adopt the code with changes, and the strip uses only the largest gap you enter: your local building department decides what applies to your guard.
Balusters Canfor lists
Rows: 4
The nominal size and the lengths Canfor prints for its pressure-treated spruce, pine and fir balusters
| Figure | Canfor prints |
|---|---|
| Nominal size, thickness by width | 2x2 |
| First length listed | 812.8 mm (32 in, as published) |
| Second length listed | 1,066.8 mm (42 in, as published) |
| Third length listed | 1,219.2 mm (48 in, as published) |
Figures in the Canfor prints column are per Canfor's product page, checked 15 Nov 2026.
Product names are trademarks of their owners. HoneyDoMath is not affiliated with, sponsored by or endorsed by these makers. Figures come from each maker's published sheets and are shown for information only.
Source: [2]
Canfor prints the nominal size and the lengths in inches; the metric figure comes first and the printed inches follow it. The strip does not use them.
Sources (2)
-
NBC 2020 Art. 9.8.8.5, openings in guards (opens in new tab), National Research Council Canada (NBC 2020), National Building Code of Canada 2020, 2nd printing including 2025 errata.
Code or government.
“openings through guards shall be of a size that prevents the passage of a spherical object having a diameter of 100 mm. (p. 853 of PDF)”
“the triangular openings formed by stair risers, stair treads and the bottom element of a required guard shall be of a size that prevents the passage of a 150 mm diam sphere. (p. 853 of PDF)”
“all guards shall be not less than 1 070 mm high. 2) All guards within dwelling units or within houses with a secondary suite including their common spaces shall be not less than 900 mm high. (p. 852 of PDF)”
Checked 15 November 2026. Figures and codes change; verify with the source. Back to where this is used (Source 1) -
Balusters (Canfor product page) (opens in new tab), Canfor, Product page, undated.
Manufacturer data.
“Nominal Dimensions TxW, inches 2x2 Lengths Inches 32, 42, 48”
Per Canfor's product page, checked 15 Nov 2026. Figures and codes change; verify with the source. Back to where this is used (Source 2)
These are summaries of what the sources say, not professional advice. Building codes and product data change. Check with your local building department and the product label about your own project.
Sources
- [1] NBC, NBC 2020 Art. 9.8.8.5, openings in guards. Checked 15 November 2026. https://nrc-publications.canada.ca/eng/view/ft/?id=515340b5-f4e0-4798-be69-692e4ec423e8&dp=2&dsl=en
- [2] Canfor, Balusters (Canfor product page). Checked 15 November 2026. https://www.canfor.com/products/outdoor-living/balusters