Baluster Spacing Calculator

Enter the clear length between two posts, the width of your balusters and the largest gap you choose, and get the count, the gap between balusters, the spacing from centre to centre and every mark to measure from.

Estimates for planning, not professional advice. Read the full notice.

Rail and balusters

Metres, centimetres or millimetres, like 3.8 m, 10 cm or 250 mm

reads as 2.5 metres, 8 feet 2 and 7 sixteenths inches

Metres, centimetres or millimetres, like 3.8 m, 10 cm or 250 mm

reads as 40 millimetres, 1 and 9 sixteenths inches

Your own figure; an example is filled in. Check the rule where you build.

reads as 90 millimetres, 3 and 9 sixteenths inches

Ends

Example: Baluster spacing strip

Summary

Balusters
19
Gap
87 mm
Spacing, centre to centre
127 mm
First baluster, left edge
87 mm
First baluster, centre
107 mm

Estimate for planning, from what you entered and the product data shown. Check product labels and your supplier before you buy.

Baluster spacing strip

Marks from the start

BalusterLeft edgeCentre
Baluster 187 mm107 mm
Baluster 2214 mm234 mm
Baluster 3341 mm361 mm
Baluster 4468 mm488 mm
Baluster 5595 mm615 mm
Baluster 6722 mm742 mm
Baluster 7849 mm869 mm
Baluster 8976 mm996 mm
Baluster 91,103 mm1,123 mm
Baluster 101,230 mm1,250 mm
Baluster 111,357 mm1,377 mm
Baluster 121,484 mm1,504 mm
Baluster 131,611 mm1,631 mm
Baluster 141,738 mm1,758 mm
Baluster 151,865 mm1,885 mm
Baluster 161,992 mm2,012 mm
Baluster 172,119 mm2,139 mm
Baluster 182,246 mm2,266 mm
Baluster 192,373 mm2,393 mm

Drawing

Baluster spacing strip

A strip of 19 balusters. The mark table lists every mark.

Scale 1:20 when printed at 100% (actual size).

Check this bar with a ruler: 100 mm.

Example: a rail with balusters

19 balusters

  • Balusters 19 balusters
  • Handrail 3 handrail lengths, metres
  • Balusters 19
  • Handrail, Handrail length, metres 3

Share this project

This link carries:

    The project is inside the link, after the # sign. Browsers do not send that part to the site.

    Questions

    How many balusters do I need for a guard?

    Enter the clear length between the posts, the baluster width and the largest gap you choose. The calculator finds the fewest balusters that keep every gap at or under that gap, then shares the space evenly between them.

    Why does the page not state a rule for the gap?

    The largest gap is your own entry, with an example filled in. The rule that applies depends on where you build, so check it with your municipal building department; this page only lays out the balusters for the gap you choose.

    Can the balusters sit flush to the posts?

    Yes. Choose flush to both ends, or flush at the start only, and the calculator recounts the balusters and the gaps for that layout.

    Worked example: a rail with balusters

    Show the steps
    1. Balusters: the fewest that leave every gap at or under the largest gap, rounded up once 2.5 m (8 ft 2 7/16 in) ÷ 90 mm (3 9/16 in) = 19 balusters
    2. Gap: the clear length less the width of every baluster, shared between the gaps (one more gap than balusters) 2.5 m (8 ft 2 7/16 in) = 87 mm (3 7/16 in)
    3. Spacing from centre to centre: the gap plus one baluster width 87 mm (3 7/16 in) + 40 mm (1 9/16 in) = 127 mm (5 in)
    4. First baluster, left edge: one gap from the post 87 mm (3 7/16 in) = 87 mm (3 7/16 in)
    5. First baluster, centre: the left edge plus half a baluster width 87 mm (3 7/16 in) = 107 mm (4 3/16 in)

    Baluster marks for this example

    Where each baluster sits, measured from the start of the clear length: left edge, centre and right edge

    Where each baluster sits, measured from the start of the clear length: left edge, centre and right edge
    BalusterLeft edgeCentreRight edge
    Baluster 1 87 mm (3 7/16 in)107 mm (4 3/16 in)127 mm (5 in)
    Baluster 2 214 mm (8 7/16 in)234 mm (9 3/16 in)254 mm (10 in)
    Baluster 3 341 mm (1 ft 1 7/16 in)361 mm (1 ft 2 3/16 in)381 mm (1 ft 3 in)
    Baluster 4 468 mm (1 ft 6 7/16 in)488 mm (1 ft 7 3/16 in)508 mm (1 ft 8 in)
    Baluster 5 595 mm (1 ft 11 7/16 in)615 mm (2 ft 3/16 in)635 mm (2 ft 1 in)
    Baluster 6 722 mm (2 ft 4 7/16 in)742 mm (2 ft 5 3/16 in)762 mm (2 ft 6 in)
    Baluster 7 849 mm (2 ft 9 7/16 in)869 mm (2 ft 10 3/16 in)889 mm (2 ft 11 in)
    Baluster 8 976 mm (3 ft 2 7/16 in)996 mm (3 ft 3 3/16 in)1.016 m (3 ft 4 in)
    Baluster 9 1.103 m (3 ft 7 7/16 in)1.123 m (3 ft 8 3/16 in)1.143 m (3 ft 9 in)
    Baluster 10 1.23 m (4 ft 7/16 in)1.25 m (4 ft 1 3/16 in)1.27 m (4 ft 2 in)
    Baluster 11 1.357 m (4 ft 5 7/16 in)1.377 m (4 ft 6 3/16 in)1.397 m (4 ft 7 in)
    Baluster 12 1.484 m (4 ft 10 7/16 in)1.504 m (4 ft 11 3/16 in)1.524 m (5 ft)
    Baluster 13 1.611 m (5 ft 3 7/16 in)1.631 m (5 ft 4 3/16 in)1.651 m (5 ft 5 in)
    Baluster 14 1.738 m (5 ft 8 7/16 in)1.758 m (5 ft 9 3/16 in)1.778 m (5 ft 10 in)
    Baluster 15 1.865 m (6 ft 1 7/16 in)1.885 m (6 ft 2 3/16 in)1.905 m (6 ft 3 in)
    Baluster 16 1.992 m (6 ft 6 7/16 in)2.012 m (6 ft 7 3/16 in)2.032 m (6 ft 8 in)
    Baluster 17 2.119 m (6 ft 11 7/16 in)2.139 m (7 ft 3/16 in)2.159 m (7 ft 1 in)
    Baluster 18 2.246 m (7 ft 4 7/16 in)2.266 m (7 ft 5 3/16 in)2.286 m (7 ft 6 in)
    Baluster 19 2.373 m (7 ft 9 7/16 in)2.393 m (7 ft 10 3/16 in)2.413 m (7 ft 11 in)

    Each mark is worked out from its own place in the run, then written to the nearest millimetre. Marks are never added up from the rounded spacing, which would drift.

    Balusters per section

    Balusters, gap and spacing from centre to centre for common clear lengths, at the example baluster width and largest gap

    Balusters, gap and spacing from centre to centre for common clear lengths, at the example baluster width and largest gap
    Clear lengthBalustersGapCentre to centre
    1 m (3 ft 3 3/8 in) 7 balusters90 mm (3 9/16 in)130 mm (5 1/8 in)
    1.5 m (4 ft 11 1/16 in) 11 balusters88.3 mm (3 1/2 in)128.3 mm (5 1/16 in)
    2 m (6 ft 6 3/4 in) 15 balusters87.5 mm (3 7/16 in)127.5 mm (5 in)
    3 m (9 ft 10 1/8 in) 23 balusters86.7 mm (3 7/16 in)126.7 mm (5 in)

    Every row leaves a gap at each end and uses the example baluster width and largest gap of this page.

    What the National Building Code of Canada 2020 prints for guards

    Openings through guards and guard height, Articles 9.8.8.5 and 9.8.8.3 of the National Building Code of Canada 2020, Part 9 (a model code; provinces and territories adopt it, some with changes)

    Openings through guards and guard height, Articles 9.8.8.5 and 9.8.8.3 of the National Building Code of Canada 2020, Part 9 (a model code; provinces and territories adopt it, some with changes)
    FigureValue in the code
    Sphere that must not pass through an opening, diameter 100 mm (3 15/16 in, converted)
    Sphere that must not pass through the triangular openings beside stairs, diameter 150 mm (5 7/8 in, converted)
    Guard height, at least 1,070 mm (3 ft 6 1/8 in, converted)
    Guard height within a dwelling unit, at least 900 mm (2 ft 11 7/16 in, converted)

    Source: [1]

    Model-code figures, with conditions the code lists. Provinces and territories adopt the code with changes, and the strip uses only the largest gap you enter: your local building department decides what applies to your guard.

    Balusters Canfor lists

    Rows: 4

    The nominal size and the lengths Canfor prints for its pressure-treated spruce, pine and fir balusters

    The nominal size and the lengths Canfor prints for its pressure-treated spruce, pine and fir balusters
    FigureCanfor prints
    Nominal size, thickness by width 2x2
    First length listed 812.8 mm (32 in, as published)
    Second length listed 1,066.8 mm (42 in, as published)
    Third length listed 1,219.2 mm (48 in, as published)

    Figures in the Canfor prints column are per Canfor's product page, checked 15 Nov 2026.

    Product names are trademarks of their owners. HoneyDoMath is not affiliated with, sponsored by or endorsed by these makers. Figures come from each maker's published sheets and are shown for information only.

    Source: [2]

    Canfor prints the nominal size and the lengths in inches; the metric figure comes first and the printed inches follow it. The strip does not use them.

    Sources (2)

    1. NBC 2020 Art. 9.8.8.5, openings in guards (opens in new tab), National Research Council Canada (NBC 2020), National Building Code of Canada 2020, 2nd printing including 2025 errata. Code or government.
      “openings through guards shall be of a size that prevents the passage of a spherical object having a diameter of 100 mm. (p. 853 of PDF)”
      “the triangular openings formed by stair risers, stair treads and the bottom element of a required guard shall be of a size that prevents the passage of a 150 mm diam sphere. (p. 853 of PDF)”
      “all guards shall be not less than 1 070 mm high. 2) All guards within dwelling units or within houses with a secondary suite including their common spaces shall be not less than 900 mm high. (p. 852 of PDF)”
      Checked 15 November 2026. Figures and codes change; verify with the source. Back to where this is used (Source 1)
    2. Balusters (Canfor product page) (opens in new tab), Canfor, Product page, undated. Manufacturer data.
      “Nominal Dimensions TxW, inches 2x2 Lengths Inches 32, 42, 48”
      Per Canfor's product page, checked 15 Nov 2026. Figures and codes change; verify with the source. Back to where this is used (Source 2)

    These are summaries of what the sources say, not professional advice. Building codes and product data change. Check with your local building department and the product label about your own project.